003 Relative Humidity Range *ENG
Sets the threshold for process control execution
determination at power on.
[0 to 99 / 50 / 1%RH/step]
004 Absolute Humidity Range *ENG
Sets the threshold for process control execution
determination at power on.
[0 to 99 / 6 / 1g/m3/step]
005 Interval:BW *ENG
Sets the threshold for process control execution
determination at power on.
[0 to 5000 / 250 / 1sheets/step]
006 Interval:FC *ENG
Sets the threshold for process control execution
determination at power on.
[0 to 5000 / 100 / 1sheets/step]
007 Page Cnt:BW *ENG Sets the process control page counter at power
on.
[0 to 5000 / - / 1sheets /step]
008 Page Cnt:FC *ENG
009 Non-use Time Setting(Long) *ENG
Sets the threshold for process control execution
determination at power on.
[0 to 5000 / 5000 / 1hour/step]
3531
[Non-useTime Procon :Set]
Adjusts the threshold for the process control at stand-by.
When the current condition has changed by more than the values of these SPs when
compared with the conditions at the previous operation, the process control at stand-by is
executed.
001 Non-use Time Setting *ENG [0 to 1440 / 360 / 1minute/step]
002 Temperature Range *ENG [0 to 99 / 10 / 1deg/step]
003 Relative Humidity Range *ENG [0 to 99 / 50 / 1%RH/step]
004 Absolute Humidity Range *ENG [0 to 99 / 6 / 1g/m3/step]
005 Maximum Execution Number *ENG
Adjusts the maximum execution time for the
process control at stand-by.
[0 to 99 / 10 / 1times/step]
Main SP Tables-3