4808 [Factory Setting Input]
002 Execution Flag *ENG [0 or 1 / 0 / 1 /step]
4902
[Disp ACC Data]
This SP outputs the final data read at the end of ACC execution.
A zero is returned if there was an error reading the data.
[0 to 255 / - / 1 /step]
001 R_DATA1 *ENG Photo C Patch Level 1 (8-bit)
002 G_DATA1 *ENG Photo M Patch Level 1 (8-bit)
003 B_DATA1 *ENG Photo Y Patch Level 1 (8-bit)
004 R_DATA2 *ENG Photo C Patch Level 17 (8-bit)
005 G_DATA2 *ENG Photo M Patch Level 17(8-bit)
006 B_DATA2 *ENG Photo Y Patch Level 17 (8-bit)
4918
[Man Gamma:Pht:Y]
Adjusts the offset data of the printer gamma for yellow in Photo mode.
See “Printer Gamma Correction" in the Replacement and Adjustment for how to use.
009 - ENG [Execute]
4930
[Total Regulation:Text Copy]
Sets the total regulation value.
001 FC 1 *ENG [0 to 400 / 200 / 1 /step]
002 FC 2 *ENG [0 to 400 / 200 / 1 /step]
003 Mono *ENG [0 to 400 / 100 / 1 /step]
004 Color Process *ENG [0 to 400 / 180 / 1 /step]
005 Cancel *ENG [0 to 400 / 400 / 1 /step]
Main SP Tables-4