5501 [PM Alarm] *CTL
001 PM Alarm Level
[0 to 9999 / 0 / 1 /step]
0: Alarm off
1 to 9999: Alarm goes off when Value (1 to 9999) x
1000 > PM counter
002 Original Count Alarm
[0 or 1 / 0 / – ]
0: No alarm sounds
1: Alarm sounds after the number of originals passing
through the ARDF > 10,000
5504
[Jam Alarm]
Sets the alarm to sound for the specified jam level (document misfeeds are not included).
001 Interval *CTL
[0 to 3 / 3 / 1 /step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
5505
[Error Alarm]
Sets the error alarm level.
The error alarm counter counts "1" when any SC is detected. However, the error alarm
counter decreases by "1" when an SC is not detected during a set number of copied
sheets (for example, default 1500 sheets).
The error alarm occurs when the SC error alarm counter reaches "5".
001 - *CTL [0 to 25500 / 1000 / 100/step]
5508 [CC Call] *CTL
001
Jam Remains 0: Disable, 1: Enable
Enables/disables initiating a call for an unattended paper jam.
002
Continuous Jams 0: Disable, 1: Enable
Enables/disables initiating a call for consecutive paper jams.
5. System Maintenance