003
Continuous Door Open 0: Disable, 1: Enable
Enables/disables initiating a call when the front door remains open.
011
Jam Detection: Time Length [3 to 30 / 10 / 1/step]
Sets the time a jam must remain before it becomes an “unattended paper jam”. This setting
is enabled only when SP5508-004 is set to "1".
012
Jam Detection: Continuous Count [2 to 10 / 5 / 1 /step]
Sets the number of consecutive paper jams required to initiate a call. This setting is
enabled only when SP5508-004 is set to "1".
013
Door Open: Time Length [3 to 30 / 10 / 1 /step]
Sets the length of time the door remains open before the machine initiates a call.
This setting is enabled only when SP5-508-004 is set to "1".
5515
[SC/Alarm Setting] *CTL -
With @Remote in use, these SP codes can be set to issue an SC call when an SC error
occurs. If this SP is switched off, the SC call is not issued when an SC error occurs.
001 SC Call
[0 or 1 / 1 / - ]
0: Off
1: On
002 Service Parts Near End Call
003 Service Parts End Call
004 User Call
006 Communication Test Call
[0 or 1 / 1 / - ]
0: Off
1: On
007 Machine Information Notice
008 Alarm Notice
009 Non Genuin Tonner Alarm
010 Supply Automatic Ordering Call
011 Supply Manegement Report Call
012 Jam/Door Open Call
Main SP Tables-5