153
Selection Dial / Push
This SP displays the classification (tone or pulse) of the telephone line to the access point
for embedded RCG-M. The number displayed (0 or 1) is the result of the execution of
SP5816-151. However, this setting can also be changed manually.
[0 or 1 / 0 / 1 /step]
0: Tone Dialing Phone
1: Pulse Dialing Phone
Inside Japan "2" may also be displayed:
0: Tone Dialing Phone
1: Pulse Dialing Phone 10PPS
2: Pulse Dialing Phone 20PPS
154
Outside Line Outgoing Number
The SP sets the number that switches to PSTN for the outside connection for embedded
RCG-M in a system that employs a PBX (internal line).
•
If the execution of SP5816-151 has succeeded and embedded RCG-M has
connected to the external line, this SP display is completely blank.
•
If embedded RCG-M has connected to an internal line, then the number of the
connection to the external line is displayed.
• If embedded RCG-M has connected to an external line, a comma is displayed with
the number. The comma is inserted for a 2 sec. pause.
• The number setting for the external line can be entered manually (including commas).
156
Dial Up User Name
Use this SP to set a user name for access to remote dial up. Follow these rules when setting
a user name:
• Name length: Up to 32 characters
•
Spaces and # allowed but the entire entry must be enclosed by double quotation
marks (").
157
Dial Up Password
Use this SP to set a password for access to remote dial up. Follow these rules when setting
a user name:
• Name length: Up to 32 characters
•
Spaces and # allowed but the entire entry must be enclosed by double quotation
marks (").
5. System Maintenance
462