No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
161
-01
D
BICU error: abnormal LSYNC
The error result of the self-diagnostic by the ASIC on the BICU is detected at
power on or recovery from the energy save mode.
• Defective BICU
•
Defective connection between BICU and SBU
1. Check the connection between BICU and SBU.
2. Replace the BICU.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
162
-01
D
BICU error: PCIE communication error
The link up interrupt from LYRA is not detected or the number of connection lanes
is other than 2 at power on or recovery from the energy save mode.
• Defective BICU
• Defective connection between BICU and SBU
1. Check the connection between BICU and SBU.
2. Replace the BICU.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
165 D
Copy Data Security Unit error
The copy data security board is not detected or a device check error occurs when
the copy data security function is set "ON" with the initial setting.
• Incorrect installation of the copy data security board
• Defective copy data security board
1. Reinstall the copy data security board.
2. Replace the copy data security board.