No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
-02 D FGATE OFF error: Cy
-03 D FGATE OFF error: Ma
-04 D FGATE OFF error: Ye
• The PFGATE ON signal still asserts within 5 seconds after processing finish
timing for black (-01), cyan (-02), magenta (-03) or yellow (-04) color
writing.
•
The PFGATE ON signal still asserts when the next job starts.
See SC 230 for troubleshooting details.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
240
-01
D LD error: Bk or Cy
-03 D LD error: Ma or Ye
The BICU detects an LD error a few times consecutively when the LDB unit turns on
after LDB initialization.
• Worn-out LD
• Disconnected or broken harness of the LD
1. Replace the harness of the LD.
2. Replace the laser optics housing unit.
3. Replace the BICU.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
260
-01
C Writing temperature thermistor error: Bk - Cy
-03 C Writing temperature thermistor error: Ma - Ye
SC Tables