No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
-03 D
TCSD Error
An error occurred in TPM software stack.
TPM defective
1. Replace the controller board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
880
CTL
D
File format converter (MLB) error
A request to get access to the MLB is not answered within the specified time (60
seconds).
Defective MLB
1. Replace the MLB.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
881
CTL
D
Authentication area error
Authentication application error is detected. Error data in an authentication
application reaches the management limit.
1. Turn the main power switch off and on.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
899
CTL
D
Software performance error
If the processing program shows abnormal performance and the program exits
abnormally, this SC is issued.
Controller board defective
Software defective
6. Troubleshooting