001 Edge Detection Threshold :K *ENG
[0.0 to 5.0 / 2.5 / 0.1V/step]
002 Edge Detection Threshold :C *ENG
003 Edge Detection Threshold :M *ENG
004 Edge Detection Threshold :Y *ENG
011 Edge Upper Limit *ENG [0 to 255 / 34 / 1point/step]
021 Edge Lower Limit *ENG [0 to 255 / 14 / 1point/step]
3628 [ID Pattern Timing :Set]
001 Scan: YCMK *ENG
Sets the process control pattern detection timing
with ID sensor.
[-500.0 to 500.0 / 0.0 / 0.1mm/step]
002 Detection Delay Time *ENG
Sets the detecion delay time of paper transfer.
[0 to 2500 / 0 / 1msec/step]
003 Delay Time *ENG
Sets the ID pattern delay time.
[0 to 2500 / 701 / 1msecstep]
004 MUSIC Delay Time *ENG
Sets the MUSIC delay time.
[-2500 to 2500 / 300 / 1msec/step]
3629 [-]
001 ChargeDC: Pattern1: Bk *ENG [0 to 999 / 250 / 1V/step]
002 ChargeDC: Pattern2: Bk *ENG [0 to 999 / 310 / 1V/step]
003 ChargeDC: Pattern3: Bk *ENG [0 to 999 / 370 / 1V/step]
004 ChargeDC: Pattern4: Bk *ENG [0 to 999 / 430 / 1V/step]
005 ChargeDC: Pattern5: Bk *ENG [0 to 999 / 500 / 1V/step]
011 ChargeDC: Pattern1: C *ENG [0 to 999 / 215 / 1V/step]
012 ChargeDC: Pattern2: C *ENG [0 to 999 / 290 / 1V/step]
013 ChargeDC: Pattern3: C *ENG [0 to 999 / 365 / 1V/step]
014 ChargeDC: Pattern4: C *ENG [0 to 999 / 440 / 1V/step]
Main SP Tables-3