System Service Mode
SM Appendix 8-7 M065/M066
Appendix:
SP Mode
Tables
030 to
239
The target fusing temperature for each paper type and mode can be adjusted
by the following SPs.
030 Plain:FC:Simplex:Center *ENG
[100 to 180 / 155 / 1 deg /step]
031 Plain: FC: Simplex: Ends *ENG
032 Plain:FC:Duplex:Center *ENG
033 Plain: FC: Duplex: Ends *ENG
034 Plain: BW: Simplex:Center *ENG
035 Plain: BW: Simplex: Ends *ENG
036 Plain: BW: Duplex:Center *ENG
037 Plain: BW: Duplex: Ends *ENG
038 Thin: FC: Simplex:Center *ENG
[100 to 180 / 145 / 1 deg /step]
039 Thin: FC: Simplex: Ends *ENG
040 Thin:FC:Duplex:Center *ENG
041 Thin:FC:Duplex:Ends *ENG
042 Thin: BW: Simplex:Center *ENG
043 Thin: BW: Simplex: Ends *ENG
044 Thin: BW: Duplex:Center *ENG
045 Thin:BW:Duplex:Ends *ENG
046 Thick 1: FC: Simplex:Center *ENG
[100 to 180 / 165 / 1 deg /step]
047 Thick 1: FC: Simplex: Ends *ENG
048 Thick 1: FC: Duplex:Center *ENG
049 Thick 1: FC: Duplex:Ends *ENG
050 Thick 1: BW: Simplex:Center *ENG
051 Thick 1: BW: Simplex: Ends *ENG
052 Thick 1: BW: Duplex:Center *ENG