System Service Mode
M065/M066 8-6 SM Appendix
011 Stand-By: Ends * ENG
[50 to 180 / 160 / 1 deg/step]
012
Stand-By:P-Roller * ENG
[50 to 160 / 140 / 1 deg/step]
Sets the pressure roller offset temperature. This value is one of the thresholds
to determine if the machine is at the heating roller target temperature during
warm-up.
013
Panel Off Mode: Center * ENG
[50 to 180 / 140 / 1 deg /step]
Specifies the heating roller temperature (center) in the panel off mode.
014
Panel Off Mode: Ends * ENG
[50 to 180 / 140 / 1 deg /step]
Specifies the heating roller temperature (both ends) in the panel off mode.
015
Panel Off Mode: P-Roller *ENG
[50 to 160 / 120 / 1 deg /step]
Specifies the presure roller temperature in the panel off mode.
016 Low Power: Center *ENG Specifies the heating roller
temperature (center or ends) in
the low power mode.
[30 to 180 / 40 / 1 deg /step]
017 Low Power: Ends *ENG
018
Low Power: P-Roller *ENG
[30 to 160 / 110 / 1 deg /step]
Specifies the pressure roller temperature in the low power mode.
019 Off Mode: Center *ENG Specifies the heating roller
temperature (center or ends) in
the sleep mode.
[0 to 180 / 0 / 1 deg /step]
020 Off Mode: Ends *ENG
021
Off Mode:P-Roller *ENG
[0 to 170 / 0 / 1 deg /step]