System Service Mode
SM Appendix 8-5 M065/M066
Appendix:
SP Mode
Tables
007 Paper Feed Temp:P-Roller *ENG
[0 to 160 / 90/ 1 deg/step]
008 P.Feed Temp:MThick:P-Roll:BW *ENG
[0 to 160 / 100/ 1 deg/step]
009 P.Feed Temp:MThick:P-Roll:FC *ENG
[0 to 160 / 100/ 1 deg/step]
010 Upper Limit Temp *ENG
[0 to 100 / 25/ 1 deg/step]
011 Offset: Feed Start *ENG
[0 to 100 / 20/ 1 deg/step]
012 Offset: Feed Start: M-Thick *ENG
[0 to 100 / 10/ 1 deg/step]
013
Offset: Feed Start: 600dpi: Plain1:
BW
*ENG
[0 to 100 / 25/ 1 deg/step]
014
Offset: Feed Start: 600dpi: Plain2:
BW
*ENG
[0 to 100 / 25/ 1 deg/step]
030 Offset: Feed Start: Time *ENG
[15 to 500 / 60 / 1 sec/step]
031 Offset:Feed Start:1200dpi *ENG
[0 to 100 / 15 / 1 deg/step]
033 Offset: Feed Start: Glossy *ENG
[0 to 100 / 15/ 1 deg/step]
1105 [Fusing Temperature] Fusing Temperature Adjustment
(Printing Mode, Roller Type, [Color], Simplex/Duplex)
Roller Type –> Center and Ends: Heating roller, P-Roller –> Pressure roller
Paper Type -> Plain, Thin, Thick, OHP, Middle Thick, Special
001
Fusing Ready Temp *ENG
[100 to 180 / 160 / 1 deg/step]
Specifies the heating roller target temperature for the ready condition.
002 Fusing Ready: Offset *ENG
[5 to 30 / 11 / 1 deg/step]
003 P-Roll Ready Target Temp. *ENG
[50 to 160 / 120 / 1 deg/step]
007
P-Roll Ready Temp *ENG
[0 to 150 / 20 / 1 deg/step]
Sets the heating roller offset temperature at the end of the heating roller. This
value is one of the thresholds to determine if the machine is at the heating
roller target temperature during warm-up.
010 Stand-By: Center * ENG
[50 to 180 / 160 / 1 deg/step]