System Service Mode
SM Appendix 8-13 M065/M066
Appendix:
SP Mode
Tables
1106
[Fusing Temperature Display] Fusing Temperature Display (Heating or
Pressure)
Displays the current temperature of the heating and pressure rollers.
001 Fusing Roller: Center - [–20 to 250 / 0 / 1 deg/step]
002 Fusing Roller: Ends - [–10 to 250 / 0 / 1 deg/step]
The heating roller has two lamps. One heats the center of the heating roller
and the other heats both ends of the heating roller.
003 Pressure Roller: Center - [–10 to 250 / 0 / 1 deg/step]
The pressure roller has two lamps. One heats the center of the heating roller
and the other heats both ends of the heating roller.
1108
[Ready Temp Setting]
Japan use only
007 Ready Temp Time *ENG
[22 to 60 / 43 / 0.1 sec/step]
1109 [Fusing Nip Band Check]
001 Execute -
[0 or 1 / 0 / 1]
Executes the nip band measurement
between fusing belt and pressure roller.
If the nip band width is not 8 mm, and
fusing is not good, replace the pressure
roller or install a new fusing unit.
002
Pre-Idling Time *ENG
[0 to 120 / 0 / 1 sec/step]
Specifies the fusing rotation time before executing SP1109-001.
003
Stop Time * ENG
[5 to 30 / 20 / 1 sec/step]
Specifies the time for measuring the nip.