System Service Mode
M065/M066 8-14 SM Appendix
1112 [Envir. Correct: Fusing]
001
Temp.: Threshold: Low *ENG
[10 to 23 / 17 / 1 deg/step]
Specifies the threshold temperature for low temperature condition.
002
Temp.: Threshold: High *ENG
[24 to 40 / 30 / 1 deg/step]
Specifies the threshold temperature for high temperature condition.
003
Low Temp. Correction *ENG
[0 to 15 / 5 / 1 deg/step]
Specifies the temperature correction for the heating roller. When the low
temperature condition (specified with SP1112-001) is detected, the value of this
SP is added to the heating roller temperature.
004
High Temp. Correction *ENG
[0 to 15 / 3 / 1 deg/step]
Specifies the temperature correction for the heating roller. When the high
temperature condition (specified with SP1112-002) is detected, the value of this
SP is subtracted from the heating roller temperature.
005 Offset Temp:Low *ENG
[0 to 15 / 5 / 0.1 deg/step]
006 Offset Temp:High *ENG
[0 to 15 / 3 / 0.1 deg/step]