System Service Mode
SM Appendix 8-15 M065/M066
Appendix:
SP Mode
Tables
1113 [Stand-by Mode Setting]
001 Wait Time AF Ready *ENG
[0 to 60 / 30 / 1 sec/step]
003
Wait Time AF Recovery *ENG
[0 to 60 / 10 / 1 sec/step]
Specifies the time for keeping the target temperature without any jobs after
recovery (SP1105-083).
004
Wait Time AF Job *ENG
[0 to 60 / 10 / 1 sec/step]
Specifies the time for keeping the target temperature without any jobs after a
last job.
005
P-Roll Thresh AF Ready *ENG
[0 to 160 / 120 / 1 deg/step]
Specifies the threshold temperature of the pressure roller for entering the wait
time mode (SP1-113-001).
006
P-Roll Thresh AF Job *ENG
[0 to 160 / 100 / 1 deg/step]
Specifies the threshold temperature of the pressure roller for entering the wait
time mode (SP1-113-004).
008
On/Off SW Timer *ENG
[0 to 999 / 300 / 1 sec/step]
Specifies the interval for entering the PID control from the On/Off control.

Table of Contents