System Service Mode
M065/M066 8-16 SM Appendix
1115 [Stand-by Idling]
001
Interval *ENG
[0 to 240 / 60 / 1 min/step]
Specifies the interval between idling during stand-by mode.
This idling during the stand-by mode prevents the roller deformation.
002
Idling Time *ENG
[0 to 60 / 2 / 0.1 sec/step]
Specifies the length of each idling operation during stand-by mode.
003 Idling Speed *ENG
[0 to 1 / 0 / 1 mm/sec/step]
1116
[Fusing Temp Change]
Paper Type –> MThick: Middle Thick
010
Center Temp. 1 ENG
[-10 / 10 / 0 / 1 deg/step]
Specifies the temperature correction for the heating roller (center) when the
paper width is 226 mm or more.
The start time of this SP can be adjusted with SP1116-018.
011
Ends Temp. 1 ENG
[-10 to 10 / 0 / 1 deg/step]
Specifies the temperature correction for the heating roller (ends) when the
paper width is 226 mm or more.
The start time of this SP can be adjusted with SP1116-018.
012
Center Temp. 2 ENG
[-10 to 10 / 0 / 1 deg/step]
Specifies the temperature correction for the heating roller (center) when the
paper width is 226 mm or more.
The start time of this SP can be adjusted with SP1116-019.
013
Ends Temp. 2 ENG
[-10 to 10 / 0 / 1 deg/step]
Specifies the temperature correction for the heating roller (ends) when the
paper width is 226 mm or more.
The start time of this SP can be adjusted with SP1116-019.