System Service Mode
SM Appendix 8-17 M065/M066
Appendix:
SP Mode
Tables
018
Control Time 1 ENG
[0 to 250 / 0 / 1 sec/step]
Specifies the start time of the temperature correction that is set with
SP1116-010 and -011.
The temperature correction is added when the time specified with this SP has
passed after feeding the paper.
019
Control Time 2 ENG
[0 to 250 / 0 / 1 sec/step]
Specifies the start time of the temperature correction that is set with
SP1116-012 and -013.
The temperature correction is added when the time specified with this SP has
passed after feeding the paper.
022 Center Temp.1:MThick ENG
[-10 to 10 / 0 / 1 deg/step]
023 Ends Temp.1:MThick ENG
024 Center Temp.2:MThick ENG
025 Ends Temp.2:MThick ENG
030 Center Temp.1:Other ENG
031 Ends Temp.1:Other ENG
032 Center Temp.2:Other ENG
033 Ends Temp.2:Other ENG