System Service Mode
M065/M066 8-18 SM Appendix
1117 [Idling Time AF Heater OFF]
001
After Ready ENG
[0 to 10 / 5 / 1 sec/step] DFU
Specifies the idling time without the lamp on after reaching the ready
temperature.
002
After Job End ENG
[0 to 10 / 5 / 1 sec/step]
Specifies the idling time without the lamp on after job end.
This idling prevents the heating roller overheating after job end.
1118 [Curl Temp Correction]
001
Execute Pattern *ENG
[0 to 4 / 0 / 1]
Selects the curl correction mode.
0: No curl correction mode
1: Plain in 600 dpi mode
2: Plain in 1200 dpi mode
3: Curl coefficient correction
This SP is not effective for all curl situations. Use this SP if you see a
sharp back curl after the machine recovered from "OFF mode" in a
high temperature and humidity environment.
002
Humidity Thresh 1 *ENG
[0 to 100 / 65 / 1 %]
Specifies the first threshold humidity for executing the curl correction.
003
Humidity Thresh 2 *ENG
[0 to 100 / 80 / 1 %]
Specifies the second threshold humidity for executing the curl correction.
004 Pattern 1: MM: H-Roll *ENG
[-30 to 0 / -3 / 1 deg]
005 Pattern 1: MM: P-Roll *ENG
[0 to 60 / 0 / 1 deg]
006 Pattern 1: HM: H-Roll *ENG
[-30 to 0 / 0 / 1 deg]
007 Pattern 1: HM: P-Roll *ENG
[0 to 60 / 0 / 1 deg]
008 Pattern 2: MM: H-Roll *ENG
[-30 to 0 / -5 / 1 deg]