System Service Mode
SM Appendix 8-35 M065/M066
Appendix:
SP Mode
Tables
2102
[Magnification Adjust] DFU
These values are the parameters for the automatic line position adjustment
and are adjusted at the factory. These SPs must be input only when a new
laser unit is installed.
001 Main Mag.: Bk:Standard Spd *ENG
[0 to 408 / 204 / 1 /step]
002 Main Mag.: Bk:Middle Spd *ENG
003 Main Mag.: Bk:Low Spd *ENG
004 Main Mag.: C: Standard Spd *ENG
005 Main Mag.: C: Middle Spd *ENG
006 Main Mag.: C:Low Spd *ENG
007 Main Mag.: M: Standard Spd *ENG
008 Main Mag.: M:Middle Spd *ENG
009 Main Mag.: M:Low Spd *ENG
010 Main Mag.: Y: Standard Spd *ENG
011 Main Mag.: Y:Middle Spd *ENG
012 Main Mag.: Y:Low Spd *ENG
013 Main Beam-Pitch: Bk: Dot *ENG
[–20 to 20 / 9 / 1 dot/step]
014 Main Beam-Pitch: Bk: Subdot *ENG
[–15 to 15 / -3 / 1 sub-dot/step]
015 Main Beam-Pitch: C: Dot *ENG
[–20 to 20 / 9 / 1 dot/step]
016 Main Beam-Pitch: C: Subdot *ENG
[–15 to 15 / -3 / 1 sub-dot/step]
017 Main Beam-Pitch: M: Dot *ENG
[–20 to 20 / 9 / 1 dot/step]
018 Main Beam-Pitch: M: Subdot *ENG
[–15 to 15 / -4 / 1 sub-dot/step]
019 Main Beam-Pitch: Y: Dot *ENG
[–20 to 20 / 9 / 1 dot/step]
020 Main Beam-Pitch: Y: Subdot *ENG
[–15 to 15 / -4 / 1 sub-dot/step]