System Service Mode
M065/M066 8-56 SM Appendix
041 M. Scan Shift: Left: Y *ENG
[–16000 to 16000 / 0 / 0.001 um/step]
042 M. Scan Shift: Center: Y *ENG
043 M. Scan Shift: Right: Y *ENG
044 S. Scan Shift: Left: Y *ENG
[–21000 to 21000 / 0 / 0.001 um/step]
045 S. Scan Shift: Center: Y *ENG
046 S. Scan Shift: Right: Y *ENG
047 M. Cor.: Dot: Y *ENG
[–511 to 511 / 0 / 1 dot/step]
048 M. Cor.: Subdot: Y *ENG
[–15 to 15 / 0 / 1 pulse/step]
050 Mag.Cor. Subdot: Y *ENG [–2040 to 2040 / 0 / 1 pulse/step]
051 M. Left Mag.: Subdot: Y *ENG
[–1020 to 1020 / 0 / 1 pulse/step]
052 M. Right Mag.: Subdot: Y *ENG
053 S. Cor.: 600 Line: Y *ENG
[–800 to 800 / 0 / 1 line/step]
054 S. Cor.: 600 Subdot: Y *ENG
[–2 to 2 / 0 / 0.001 line/step]
055 S. Cor.: 1200 Line: Y *ENG
[–1600 to 1600 / 0 / 1 line/step]
056 S. Cor.: 1200 Subdot: Y *ENG
[–2 to 2 / 0 / 0.001 line/step]
057 S. Cor.: 600 Subdot *ENG
[–1 to 1 / 0 / 0.001 line/step]
059 S. Cor.:1200 Subdot *ENG
[–1 to 1 / 0 / 0.001 line/step]
2182
[Line Pos. Adj. Offset] DFU
(Color) M. Scan: Main scan, S. Scan: Sub-scan
001 C Magnification *ENG Adjusts the line position manually.
[-1 to 1 / 0 / 0.001%/step]
When line shifts are not corrected
by the automatic line position
adjustment, do this SP.
Increasing a value reduces the
image in the main scan direction.
Decreasing a value enlarges the
002 M Magnification *ENG
003 Y Magnification *ENG