System Service Mode
M065/M066 8-62 SM Appendix
2193
[MUSIC Condition] DFU
Line Position Adjustment: Condition Setting
001
Auto Execution *ENG
[0 or 1 / 1 / 1 ] 0: OFF, 1: ON
Enables/disables the automatic line position adjustment.
002
Page: Job End: BW+FC *ENG
[0 to 999 / 500 / 1 page/step]
Adjusts the threshold of the line position adjustment for BW and color printing
mode after job end.
003
Page: Job End: FC *ENG
[0 to 999 / 200 / 1 page/step]
Adjusts the threshold of the line position adjustment for color printing mode
after job end.
004
Page: Interrupt: BW+FC *ENG
[0 to 999 / 200 / 1 page/step]
Adjusts the threshold of the line position adjustment for BW and color printing
mode during job.
005
Page: Interrupt: FC *ENG
[0 to 999 / 200 / 1 page/step]
Adjusts the threshold of the line position adjustment for color printing mode
during jobs.
006
Page: Standby: BW *ENG
[0 to 999 / 100 / 1 page/step]
Adjusts the threshold of the line position adjustment for BW printing mode in
stand-by mode. The line position adjustment is done when the number of
outputs in BW printing mode reaches the value specified with this SP and the
condition of SP2-193-008 or SP2-193-009 is satisfied.
007
Page: Standby: FC *ENG
[0 to 999 / 100 / 1 page/step]
Adjusts the threshold of the line position adjustment for BW printing mode in
stand-by mode. The line position adjustment is done when the number of
outputs in color printing mode reaches the value specified with this SP and the
condition of SP2-193-008 or SP2-193-009 is satisfied.
008
Temp Change *ENG
[0 to 100 / 5 / 1 deg/step]
Adjust the temperature change threshold for the line position adjustment
(Mode b: adjustment once). The timing for line position adjustment depends on