System Service Mode
SM Appendix 8-63 M065/M066
Appendix:
SP Mode
Tables
the combinations of several conditions.
009
Elapse Time *ENG
[1 to 1440 / 300 / 1 minute/step]
Adjust the time threshold for the line position adjustment (Mode b: adjustment
once). The timing for line position adjustment depends on the combinations of
several conditions.
010
Magnification *ENG
[0 to 10 / 1 / 0.1 %/step]
Adjusts the magnification threshold for line position adjustment. If the length of
the main scan is changed by this amount since the previous MUSIC, then
MUSIC is done again.
011
Temp Change 2 *ENG
[0 to 100 / 10 / 1 deg/step]
Adjust the temperature change threshold for the line position adjustment
(Mode a: adjustment twice). The timing for line position adjustment depends on
the combinations of several conditions.
012
Time 2 *ENG
[1 to 9999 / 600 / 1 minute/step]
Adjust the time threshold for the line position adjustment (Mode a: adjustment
twice). The timing for line position adjustment depends on the combinations of
several conditions.
013 Time 3 *ENG
[1 to 1440 / 300 / 1 minute/step]
014
Page: Full Color Job Before:
BW+FC
*ENG
[0 to 999 / 200 / 1 page/step]
015
Page: Full Color Job Before:
FC
*ENG
[0 to 999 / 200 / 1 page/step]
016 Page: Power ON:BW+FC *ENG
[0 to 999 / 200 / 1 page/step]