System Service Mode
SM Appendix 8-65 M065/M066
Appendix:
SP Mode
Tables
2199 [Music Time Setting] DFU
001 Error Time Set *ENG
[0.1 to 9.9 / 3 / 0.1 sec /step]
2220
[Skew Origin Set]
Resets the value of the skew adjustment motor for each color.
These SPs must be executed when a new laser optics housing unit is installed.
001 C:Skew Motor *ENG
-
002 M:Skew Motor *ENG
003 Y:Skew Motor *ENG
2229
[Dev. DC Bias:Fixed] DFU
Development DC Bias Adjustment
Adjusts the development bias.
Development bias is automatically adjusted during process control; therefore,
adjusting these settings has no effect while Process Control (SP3-041-001
Default: ON) is activated.
After deactivating Process Control with SP3-041-001, the values in these SP
modes are used for printing.
001 Bk *ENG
[0 to 800 / 450 / 1 –V/step]
002 C *ENG
003 M *ENG
004 Y *ENG