System Service Mode
M065/M066 8-66 SM Appendix
2241
[Ambient Temp/Hum:Display]
Displays the environment temperature and humidity.
001 Temperature -
[–1280 to 1270 / 0 / 0.1 deg/step]
002 Relative Humidity -
[0 to 1000 / 0 / 0.1 %RH/step]
003 Absolute Humidity -
[0 to 100 / 0 / 0.01 g/m
3
/step]
2302
[Env. Correct:Transfer] DFU
Environmental Correction: Image Transfer Belt Unit
002
Forced Setting *ENG
[0 to 6 / 0 / 1 /step]
Sets the environment condition manually.
0: Automatic environment control
1: LL (Low temperature/ Low humidity)
2: ML (Middle temperature/ Low humidity)
3: MM (Middle temperature/ Middle humidity)
4: MH (Middle temperature/ High humidity)
5: HH (High temperature/ High humidity)
6: SLL (Super low temperature/ low humidity)
003
Absolute Humidity: Threshold 1 *ENG
[0 to 100 / 4 / 0.01 g/m
3
/step]
Adjusts the threshold value between LL and ML.
004
Absolute Humidity: Threshold 2 *ENG
[0 to 100 / 8 / 0.01 g/m
3
/step]
Adjusts the threshold value between ML and MM.
005
Absolute Humidity: Threshold 3 *ENG
[0 to 100 / 16 / 0.01 g/m
3
/step]
Adjusts the threshold value between MM and MH.
006
Absolute Humidity: Threshold 4 *ENG
[0 to 100 / 24 / 0.01 g/m
3
/step]
Adjusts the threshold value between MH and HH.

Table of Contents