System Service Mode
M065/M066 8-198 SM Appendix
3236
[Toner Supply Consum.: Display] DFU
Displays the toner amount of the latest toner supply for each color.
001 Latest: Bk *ENG
[0 to 40000 / 0 / 0.1 mg/step]
002 Latest: C *ENG
003 Latest: M *ENG
004 Latest: Y *ENG
3237
[Developer Agitation Setting]
Displays the toner amount of the latest toner supply for each color. DFU
001 Agitation Time *ENG
[0 to 200 / 5 / 1 sec/step]
3238
[Vt Target: Setting]
Displays the Vt target value at developer initialization. DFU
001 Bk *ENG
[0 to 5 / 2.7 / 0.01 V/step]
002 C *ENG
003 M *ENG
004 Y *ENG
3239
[Vtref Correction: Setting]
Adjusts the parameter for Vtref correction at the process control.
001 (+)Consumption: Bk *ENG
[0 to 1 / 0.08 / 0.01 V/step]
002 (+)Consumption: C *ENG
003 (+)Consumption: M *ENG
004 (+)Consumption: Y *ENG
005 (-)Consumption: Bk *ENG
006 (-)Consumption: C *ENG