System Service Mode
SM Appendix 8-199 M065/M066
Appendix:
SP Mode
Tables
007 (-)Consumption: M *ENG
008 (-)Consumption: Y *ENG
009-012 Threshold for development gamma rank.
009 P Rank 1 Threshold *ENG
[0 to 2 / 0.5 / 0.01 /step]
010 P Rank 2 Threshold *ENG
[0 to 2 / 0.25 / 0.01 /step]
011 P Rank 3 Threshold *ENG
[-2 to 0 / -0.25 / 0.01 /step]
012 P Rank 4 Threshold *ENG
[-2 to 0 / -0.5 / 0.01 /step]
013-014 Threshold for image density rank on the image transfer belt.
013 T Rank 1 Threshold *ENG
[-1 to 0 / -0.16 / 0.01 V/step]
014 T Rank 2 Threshold *ENG
[0 to 1 / 0.16 / 0.01 V/step]
015 Correct Value Coef *ENG
[1 to 2.5 / 9.99 / 0.01 /step]
3241 [Background Potential Setting]
001 Coefficient: Bk *ENG These are parameters for calculating the
charge bias referring to the development
bias at process control.
[-1000 to 1000 / 0 / 1 /step]
DC charge bias = Development bias x (1 +
0.001 x these vales) + SP3-241-005 to -008
002 Coefficient: C *ENG
003 Coefficient: M *ENG
004 Coefficient: Y *ENG
005 Offset: Bk *ENG These are additional values for calculating
the charge bias referring to the
development bias at process control.
[0 to 255 / 158 / 1 V/step]
DC charge bias = Development bias x (1 +
0.001 x SP3-241-001 to -004) + these
values
006 Offset: C *ENG
007 Offset: M *ENG
008 Offset: Y *ENG

Table of Contents