Installation Requirements 
 
SM 2-1 M095/M096/M099/M100 
Installation 
2. INSTALLATION 
2.1 INSTALLATION REQUIREMENTS 
2.1.1 ENVIRONMENT 
 
1.  Temperature Range: 10°C to 32°C (50°F to 89.6°F) 
2.  Humidity Range: 15% to 80% RH 
3.  Ambient Illumination: Less than 2,000 lux (do not expose to direct sunlight) 
4.  Ventilation: 3 times/hr/person 
5.  Do not put the machine in areas that get sudden temperature changes. This includes:   
  Areas directly exposed to cool air from an air conditioner 
  Areas directly exposed to heat from a heater. 
6.  Do not put the machine in areas that get exposed to corrosive gas. 
7.  Do not install the machine at locations over 2,000 m (6,560 ft.) above sea level. 
8.  Put the machine on a strong, level base. (Inclination on any side must be no more than 5 
mm.) 
9.  Do not put the machine in areas with strong vibrations. 
2.1.2 MACHINE LEVEL 
Front to back: Within 5 mm (0.2") of level 
Right to left: Within 5 mm (0.2") of level