Service Call Conditions 
 
SM 5-13 M095/M096/M099/M100 
System 
Maintenance 
Reference 
SC 5xx (Motor and Fusing Error) 
 
500 
Transport/Fusing Motor Error 
The LOCK signal error is detected when the EGB monitors the transport/fusing 
motor state. (This monitoring is done immediately after power-on, when the motor 
starts rotating, and immediately after the motor stops.) 
  Disconnected or defective motor harness. 
  Motor slips due to excessive load   
1.  Check the harness from the transport/fusing motor. Replace it if 
necessary. 
 
530 
LSU Fan Motor Error 
A LOCK signal is not detected for more than ten seconds while the motor START 
signal is on and if this error occurs twice consecutively, this SC is issued. 
  Disconnected or defective motor harness. 
  Defective LSU fan motor 
1.  Check or replace the motor harness. 
2.  Replace the LSU fan motor. 
 
531 
Fusing Fan Motor Error 
A LOCK signal is not detected for more than ten seconds while the motor START 
signal is on and if this error occurs twice consecutively, this SC is issued. 
  Disconnected or defective motor harness. 
  Defective LSU fan motor 
1.  Check or replace the motor harness. 
2.  Replace the fusing fan motor.