Factory SP Settings
SM 4-11 D255/D256/M281/M282
Replacement
and Adjustment
SP No. SP Name Default Value
Factory
Setting
SP4-611-002 Gray Balance Set: B: DF Scan -100 digit -- digit
*1
SP5-101-107
Auto Logout Timer: Auto Logout
Time
1: Enable 0: Disable
SP5-305-101 Auto Off Set: Set Function 1: Enable 0: Disable
SP5-748-201
OpePanel Setting: Cheetah Panel
Connect Setting
0: Not connected
1:
Connected
SP5-805-002 Drum Heater
NA/EU :0 (Off)
AP: 1 (ON)
NA/EU :0
(Off)
AP: 1 (ON)
SP5-875-001 SC Auto Reboot: Reboot Setting
0: The machine
reboots
automatically
when the
machine issues
an SC error and
logs the SC error
code.
1: The
machine
does not
reboot when
an SC error
occurs.
SP5-907-001 Plug & Play Maker/Model Name 0
0 or 9
(Set the
appropriate
setting for
the model)
SP5-985-001 Device Setting: On Board NIC 0: Disable 1: Enable
SP5-985-002 Device Setting: On Board USB 0: Disable 1: Enable
SP6-006-001
ADF Adjustment: Side-to-Side
Regist: Front
+0.0 mm -- mm
*1
SP6-026-001
ADF Timing Adjustment: Leading
Edge Start Timing: Front
+0 pulse -- pulse
*1
SP6-026-003
ADF Timing Adjustment: Leading
Edge End Timing: Front
-16 pulse -- pulse
*1