Service Call 101-195
D255/D256/M281/M282 6-10 SM
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC141-00 D Black level detection error
The black level cannot be adjusted to the target level at the time
of applying power source for scanner (when the main power is
turned ON).
Scanner Carriage defective
BiCU defective
Harness defective
IOB defective
Check if the SC occurs by turning the power OFF then ON. If the
SC occurs again, do the following steps. Check if the SC
reoccurs by cycling the power after each step.
1. Reconnect the following connectors.
Scanner Carriage – BiCU connector
BiCU – IOB connector
2. Scanner carriage defective
Replace the scanner carriage.
3. BiCU defective
Replace the BiCU.
4. Harness defective
Replace the following harnesses.
Scanner Carriage – BiCU harness
BiCU – IOB harness
5. IOB defective
Replace the IOB.