Service Call 501-582
D255/D256/M281/M282 6-40 SM
SC No. Type Error Name/Error Condition/Major Cause/Solution
Fusing thermistor connection PCB defective
Replace the fusing thermistor connection PCB.
IOB defective
1. Update the engine software to the latest version.
2. Replace the IOB.
PSU defective
1. Reconnect the following connector.
PSUIOB connector
2. Replace the PSU.
Fusing lamp defective
Replace the fusing unit.
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC551-00 D Fusing Thermistor (End) Disconnected Error
Input from fusing thermistor (end) is 1019 or more (A/D value)
continuously for 4 seconds.
Connector defective or disconnected
Connector pin defective
Triac defective
Fusing thermistor defective
Fusing thermistor connection PCB defective
IOB defective
Connector defective or disconnected
Reconnect the following connectors.
Fusing ThermistorFusing Thermistor Connection
PCB connector
Fusing Thermistor Connection PCB IOB connector
Connector pin defective
If the I/F connector pins of the fuser unit and the main unit
are deformed owing to foreign materials, replace the
connectors or the units including the connectors.