Service Call 501-582
SM 6-43 D255/D256/M281/M282
Troubleshooting
SC No. Type Error Name/Error Condition/Major Cause/Solution
Temperature sensor defective
1. Reconnect the following connector.
Temperature SensorIOB connector
2. If the connector is broken, shorted, or grounded,
replace the connector.
3. Replace the temperature sensor.
IOB defective
1. Update the engine software to the latest version.
2. Replace the IOB.
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC582-00 C Temperature Sensor Shorted Error
The average of the output from the temperature sensor is 31 or
less for 5 seconds.
Temperature sensor defective
IOB defective
Temperature sensor defective
1. Reconnect the following connector.
Temperature SensorIOB connector
2. If the connector is broken, shorted, or grounded,
replace the connector.
3. Replace the temperature sensor.
IOB defective
1. Update the engine software to the latest version.
2. Replace the IOB.