Service Call 622-691
D255/D256/M281/M282 6-50 SM
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC668-00 D SPI Communication Error
The SPI communication error cannot be recovered within 10
seconds after the error occurred.
The error recovery does not finish normally.
FFC defective or disconnected
BiCU defective
IOB defective
1. Turn the main power OFF/ON.
2. Reconnect the FFC between BiCU and IOB.
3. Replace the FFC between BiCU and IOB.
4. Replace the BiCU.
5. Replace the IOB.
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC669 EEPROM Communication Error
SC669-01 D EEPROM OPEN: ID error
SC669-02 D EEPROM OPEN: Channel error
SC669-03 D EEPROM OPEN: Device error
SC669-04 D EEPROM OPEN: Communication abort error
SC669-05 D EEPROM OPEN: Communication timeout error
SC669-06 D EEPROM OPEN: Operation stopped error
SC669-07 D EEPROM OPEN: Buffer full
SC669-08 D EEPROM OPEN: No error code
SC669-09 D EEPROM CLOSE: ID error
SC669-10 D EEPROM CLOSE: No error code
SC669-11 D EEPROM Data write: ID error
SC669-12 D EEPROM Data write: Channel error
SC669-13 D EEPROM Data write: Device error