Service Call 816-899
D255/D256/M281/M282 6-62 SM
No. Type Error Name/Error Condition/Major Cause/Solution
SC817-00 D Monitor error: File detection / Digital signature error (MP 501/601
Only)
Bootloader cannot read any of diagnostic module, kernel, or
root filesystem.
In a bootloader SD card, the digital signature checking for
any of diagnostic module, kernel, or root filesystem is failed.
Any of the following items does not exist or is broken OS
Flash ROM, Diagnostic module in SD card, Kernel, Root
filesystem
Any of the following items is revised fraudulently: Diagnostic
module in SD card, Kernel, Root filesystem
ROM update for controller system
Use another booting SD card having a valid digital signature
No. Type Error Name/Error Condition/Major Cause/Solution
SC819-00 D Kernel halt error
[xxxx]: Detailed error code
Due to a control error, a RAM overflow occurred during system
processing. One of the following messages was displayed on the
operation panel.
[0x5032] HAIC-P2 error
HAIC-P2 decompression error (An error occurred in the ASIC
compression/decompression module.)
The code data saved in the HDD was broken for an
unexpected reason. (HDD device defective)
The code data saved to memory was broken for an
unexpected reason. (Memory device defective)
ASIC defective
Data other than code data was unzipped due to a software
malfunction.