Service Call 816-899
D255/D256/M281/M282 6-64 SM
No. Type Error Name/Error Condition/Major Cause/Solution
Received file system data was broken even if the initialization
succeeds and there was no error reply from the HDD.
Power supply disconnection during data writing to the HDD.
Replace the HDD.
This SC may occur when turning on the machine for the first time
with a new HDD. In this case, turn the main power OFF/ON.
[0x696e] gwinit processing end
If the SCS process is ended for some reason
If an unexpected error occurs at SCS processing end, gwint
processing also halts (this result is judged a kernel stop error, by
gwinit specification)
"0x69742064" -> "init died"
Turn the main power OFF/ON.
[0x766d] VM full error
Occurs when too much RAM is used during system processing
"vm_pageout: VM is full"
Turn the main power OFF/ON.
Console
string
Other error (characters on operation panel)
System detected internal mismatch error
Software defective
Insufficient memory
Hardware driver defective (RAM, flash memory, CPU)
Replace with a larger capacity RAM, or flash memory.
Replace the controller board.
Replace the connected controller option with a new one.