Service Call 816-899
SM 6-75 D255/D256/M281/M282
No. Type Error Name/Error Condition/Major Cause/Solution
SC864-02
to 23
D HDD data CRC error
During HDD operation, the HDD cannot respond to a CRC error
query. Data transfer did not execute normally while data was
being written to the HDD.
Bad sectors were generated during operation.
(An error occurred in partition "a" (SC864-02) to partition "v"
(SC864-23)).
Format the HDD.
Replace the HDD.
No. Type Error Name/Error Condition/Major Cause/Solution
SC865-00 D HD access error
During HDD operation, the HDD returned an error.
The HDD returned an error that does not constitute SC863 (bad
sector) or SC864 (CRC error).
Replace the HDD.
No. Type Error Name/Error Condition/Major Cause/Solution
SC865-01 D HDD access error
During HDD operation, the HDD returned an error.
The HDD returned an error that does not constitute SC863 (bad
sector) or SC864 (CRC error).
(An error occurred in an area that does not belong to a partition,
such as the disk label area.)
Replace the HDD.