Service RAM Addresses
D255/D256 FAX OPTION 146 SM
6A72EE(H) - SIP digest authentication password (Max. 128 characters - ASCII)
6A736E(H) - Gateway address information (Max. 7100 characters - ASCII)
6A8F2A(H) - NGN initial setting method 0: Simple, 1: Manual
6A8F2B(H) - SIP digest authentication user name (Max. 128 characters - ASCII)
6A8FAB(H) - NGN-SIP domain name (Max. 64 characters - ASCII)
6A8FEB(H) - NGN-home gateway address (Max. 128 characters - ASCII)
6A906C(H) - Stand-by port number for H.323 connection
6A906E(H) - Stand-by port number for SIP connection
6A9070(H) - RAS port number
6A9072(H) - Gatekeeper port number
6A9074(H) - Port number of data waiting for T.38
6A9076(H) - Port number of SIP server
6A9078(H) - Priority for SIP and H.323 0: H.323, 1: SIP
6A9079(H) - SIP function 0: Disabled, 1: Enabled
6A907A(H) - H.323 function 0: Disabled, 1: Enabled
6A907B(H) - SIP digest authentication function 0: Disabled, 1: Enabled
6B3AE4(H) - 6B3B04 (H) - Dial tone detection parameter (Max. 11 x 3 lines)
This initializes following order. [0x04, 0x40, 0x03, 0x60, 0x64, 0xf4, 0x01,0x64, 0x04, 0xc8, 0x00]
6B3AE4(H) Dial tone detection frequency Upper limit (High)
Defaults: NA: 06, EU: 06, ASIA: 06
6B3AE5(H)Dial tone detection frequency Upper Limit (Low)
Defaults: NA: 50, EU: 50, ASIA: 50
6B3AE6(H)Dial tone detection frequency Lower Limit (High)
Defaults: NA: 03, EU: 02, ASIA: 02
6B3AE7(H)Dial tone detection frequency Lower Limit (Low)
Defaults: NA: 60, EU: 90, ASIA: 90
6B3AE8(H)Dial tone detection waiting time (20 ms)
Defaults: NA: 64, EU 64, ASIA: 64
6B3AE9 to 6B3AEADial tone detection monitoring time (20 ms)
Defaults
Area 6B35A9 6B35AA
NA F4 01
EU F4 01
ASIA F4 01
6B3AEB(H)Dial tone detect judge time (20 ms)