Engine SP Mode
SM 5-20 D245/D246/D247
2-303-004
Deve Cooldown - *ENG [0 to 20 / 4 / 1 –uA / step]
Adjusts to improve the toner cleaning performance at the development bias
deactivating.
2304 [Transfer Curr Dir]
Specifies the transfer current manually for each side.
2-304-001
Input:1side ENG [0 to 30 / 0 / 1 uA / step]
2-304-002
Input:2side ENG [0 to 30 / 0 / 1 uA / step]
2305 [Transfer Curr Set]
2-305-001
Non Image Area *ENG [3 to 30 / 10 / 1 uA / step]
Adjusts the transfer current for non-image area when backside
contamination occurred that is caused by reverse polarity toner on the
transfer roller or weak charging toner on the drum.
2-305-002
TR Anti-Static Pr *ENG [3 to 30 / 10 / 1 uA / step]
Adjusts the discharge current at pre-charging.
2-305-003
TR Anti-Static Re *ENG [3 to 30 / 10 / 1 uA / step]
Adjusts the discharge current at charging.
2306 [Transfer Curr Tem]
Adjusts the machine ambiense temperature for the reference table of the
transfer current adjustment.
2-306-001
Temp Inside Machi *ENG [0 to 99 / 20 / 1 deg / step]