SNMPv3 Encryption
When using SmartDeviceMonitor for Admin/Device Manager NX Lite or another application that
communicates via SNMPv3, you can encrypt the data transmitted.
By making this setting, you can protect data from being tampered with.
1. Log in as the network administrator from the control panel.
2. Press [System Settings].
3. Press [Interface Settings].
4. Press [ Next].
5. Press [Permit SNMPv3 Communication].
6. Press [Encryption Only].
7. Press [OK].
8. Log out.
To use SmartDeviceMonitor for Admin/Device Manager NX Lite for encrypting the data for
specifying settings, you need to specify the network administrator's [Encryption Password] setting
and [Encryption Password] in [SNMP Authentication Information] in SmartDeviceMonitor for
Admin/Device Manager NX Lite, in addition to specifying [Permit SNMPv3 Communication] on
the machine. For details about specifying [Encryption Password] in SmartDeviceMonitor for
Admin/Device Manager NX Lite, see SmartDeviceMonitor for Admin/Device Manager NX Lite
Help.
If network administrator's [Encryption Password] setting is not specified, the data for transmission
may not be encrypted or sent. For details about specifying the network administrator's [Encryption
Password] setting, see page 19 "Registering and Changing Administrators".