Depending on the values of the settings for [Max. Allowed No. of Access] and [Measurement
Time], you may frequently receive violation detection e-mail.
If violation detection e-mail is received frequently, check the content and review the setting values.
Device Access Violation
This can be specified by the machine administrator.
If the number of log in requests exceeds the setting, the system classifies the access session as an
access violation. The access session is recorded in the Access Log and the log data is sent to the
machine administrator by e-mail. Also, a message is displayed on the control panel and on Web
Image Monitor.
If the "Max. Allowed No. of Access" is set to [0], over access is not detected.
In "Authentication Delay Time", you can specify response delay time for log-in requests to prevent
the system from becoming unavailable when an access violation is detected.
In "Simultns. Access Host Limit", you can specify the limit number of hosts accessing the machine at
one time. If the number of access exceeds the setting, monitoring becomes unavailable and the
detected unavailability is recorded in the Log.
Max. Allowed No. of Access
Specify the maximum number of allowable access attempts.
Use the number keys to enter the number between "0" and "500", and then press [
].
Default: [100]
Measurement Time
Specify the interval to count the number of excessive access. When the measurement time is
over, the logged counts of access are cleared.
Use the number keys to enter the number between "10" and "30", and then press [ ].
Default: [10]
Authentication Delay Time
Specify the authentication delay time when an access violation is detected.
Use the number keys to enter the number between "0" and "9", and then press [ ].
Default: [3]
Simultns. Access Host Limit
Specify the number of acceptable authentication attempts when authentications are delayed
due to an access violation.
Use the number keys to enter the number between "50" and "200", and then press [ ].
Default: [200]
Specifying the Extended Security Functions
263

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh MP C2503 Series and is the answer not in the manual?

Ricoh MP C2503 Series Specifications

General IconGeneral
FunctionsPrint, Copy, Scan
Print TechnologyLaser
Max Print Resolution1200 x 1200 dpi
Copy Resolution600 x 600 dpi
Scan Resolution600 x 600 dpi
Automatic DuplexingYes
Paper Output Capacity (Standard)500 sheets
Processor600 MHz
Memory (Standard)1.5 GB
Hard Disk Drive250 GB
Power Source220 - 240 V, 50/60 Hz
Print Speed25 ppm (Black/Color)
ConnectivityUSB, Ethernet
Copy Speed25 ppm (Black/Color)
Zoom25% - 400%
Scan SpeedUp to 54 ipm (Black/Color)
Paper Input Capacity (Standard)350 sheets
Paper SizeA3, A4, A5, B4, B5
Paper Weight60 - 220 g/m²
PDLPCL6, PostScript 3