Chapter 2 Command System  RIGOL 
MSO1000Z/DS1000Z Programming Guide  2-113 
The number of negative pulses that fall from above the threshold upper limit to 
below the threshold lower limit. 
 
The number of rising edges that rise from below the threshold lower limit to above 
the threshold upper limit. 
 
 
The number of falling edges that fall from above the threshold upper limit to below 
the threshold lower limit. 
 
 
3.  Delay and Phase 
The time difference between the rising edges of source 1 and source 2. Negative 
delay indicates that the selected rising edge of source 1 occurred after the selected 
rising edge of source 2. 
The time difference between the falling edges of source 1 and source 2. Negative 
delay indicates that the selected falling edge of source 1 occurred after the selected 
falling edge of source 2. 
Phase difference calculated according to "Delay  1→2" and the period of source 
1, expressed in degree. The calculation formula is as shown below. 
Phase difference calculated according to "Delay  1→2" and the period of source 
1, expressed in degree.The calculation formula is as shown below. 
360
1
Delay
Phase
Period
  
 
Wherein, 
  denotes "Phase  1→2" or "Phase  1→2", 
  denotes "Delay  1→2" 
or "Delay  1→2" and 