52 WisDom User Manual
Quick
Key
Function Description
5 Anti-
Code
If defined by your engineer the WisDom can be defined
to be not ready to Set after an alarm or tamper condition.
To restore the system to Normal Operation mode, an
engineer code or an Anti-code must be entered. Entering
the code supplied by the engineer at this location will
restore the system to the Normal Operation mode.
6 Duress
Restore
Deactivates a latched PO that has been activated as a
result of a duress code being entered
7 Enable
Engineer
Enables the Grand Master, Manager or Master to
authorise the engineer for a time window of 1 hour to use
his code for user functions programming
8 Engineer
Reset
Enables the engineer to reset an alarm. The option is
available only if the user authorized the engineer in
location [2][7]
9 Check
Credit
Use this function to receive information by SMS of the
credit level in your Prepaid SIM card. Once the SMS is
received by the provider, the SIM’s credit level is sent
back and displayed on the keypad's LCD display or sent
to the Follow Me (if defined).
0 More… 1) User Call: This option is used to receive the SIM
credit level using the voice channel.
2) Reset SIM: After charging a prepaid SIM card, the
user has to reset the SIM Expire Time manually. The
time duration for expiration is defined by your engineer.
3 View
1 Faults Should be used when the system has detected a
problem, which is evidenced by the rapid flashing of the
Fault LED.
To delete a fault from the list, after it has been repaired,
change the status of the fault to Y using the
key.
2 Alarm
Memory
Allows the viewing of the five most recent alarm
conditions stored by the system, by partition.