66 SteelFusion Edge Hardware and Maintenance Guide
Replacing SteelFusion Edge Components Adding and replacing memory modules
13. Align the memory-module edge connector with the slot alignment keys and insert it into the slot.
The module slot has two alignment keys that allow you to install the module in only one direction.
(Figure 4-31.)
Figure 4-31. Inserting the memory modules into the connector slot and securing
14. Press down on the memory module with your thumbs while pulling up on the ejectors with your index
fingers to lock the module into the slot.
15. Ensure that all ejector tabs are in the upright locked position.
16. Repeat Step 6 to Step 11 to install the remaining memory modules.
17. Reinstall the cooling shroud.
18. Reinstall the QPI module.
19. Connect the power wires for the QPI module.
20. Reinstall the small cooling shrouds.
21. Reinstall the chassis cover.