Bulletin 280G/281G Programmable Parameters 3-17
Zone #2 MAC ID
The node address of the device
whose data is to be consumed
for zone 2
Parameter Number 71
Access Rule GET/SET
Data Type USINT
Group ZIP Parameters
Units
MinimumValue 0
Maximum Value 64
Default Value 64
Zone #3 MAC ID
The node address of the device
whose data is to be consumed
for zone 3
Parameter Number 72
Access Rule GET/SET
Data Type USINT
Group ZIP Parameters
Units
MinimumValue 0
Maximum Value 64
Default Value 64
Zone #4 MAC ID
The node address of the device
whose data is to be consumed
for zone 4
Parameter Number 73
Access Rule GET/SET
Data Type USINT
Group Misc. Option
Units
MinimumValue 0
Maximum Value 64
Default Value 64
Zone #1 Health
Read Only consumed connection
status for zone 1
0 = Healthy
1 = Unhealthy
Parameter Number 74
Access Rule GET
Data Type BOOL
Group ZIP Parameters
Units
MinimumValue 0
Maximum Value 1
Default Value 0
Zone #2 Health
Read Only consumed connection
status for zone 2
0 = Healthy
1 = Unhealthy
Parameter Number 75
Access Rule GET
Data Type BOOL
Group ZIP Parameters
Units
MinimumValue 0
Maximum Value 1
Default Value 0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation ArmorStart Bulletin 280G and is the answer not in the manual?

Rockwell Automation ArmorStart Bulletin 280G Specifications

General IconGeneral
BrandRockwell Automation
ModelArmorStart Bulletin 280G
CategoryController
LanguageEnglish

Related product manuals