Chapter 5 Operating
2104.6536.72 - 5.28 - E-1
The following illustration shows that the testTrap has been received correctly by the unit
with the serial number 100111.
Known problems
If querying the data does not work or if you do not receive an alarm, check the following:
Has the network been connected correctly? Does the SNMP connection function exclu-
sively via the remote Ethernet interface of the device (R&S NetCCU800: X5NETLINK,
R&S Sx800/SX801: X2, R&S xLx8000: X32ETHERNET REMOTE)?
Are the network settings (IP address, gateway) correct?
Has the correct Community been entered for accessing the manager and the transmitter
(case-sensitive)?
Is a PC firewall blocking incoming SNMP packets?