Chapter 5 Operating
2104.6536.72 - 5.45 - E-1
3.1.4 Status (for ATV)
LP1 MIP fail W No MIP at input TS 2. Possible reasons:
– in the SFN: no MIP in input data stream
– in MFN: No MIP in the input data stream and in the menu win-
dow TV Settings > DVB > TPS, the setting TPS Source >
MIP is selected
- OFF - MIP is present
Display LED Explanation
Sum Fault F Sum Fault: One or more errors occurred
RF On RF level at the exciter output is OK
F There is no RF level at the exciter output even though the RF
output is enabled
- OFF - No RF level at output of exciter since the RF output is not
enabled (manual disabling)
Exciter On RF output of the exciter is enabled
There are several ways of enabling the RF output:
– using the setting item RF Output in the RF Out > Output
menu
– on the front panel of the instrument via the RF ON/OFF key
Loop Ok RF loop closed
- OFF - RF loop not closed
Video In Ok Valid video signal is present at the input
W Invalid video signal at input
F No video signal at input
Option Key Ok All necessary software options are enabled
W A temporary license code for a software option will expire shortly
F One or more necessary software options are not enabled
Display LED Explanation