Chapter 5 Operating
2104.6536.72 - 5.58 - E-1
Settings that are not saved in parameter sets
Certain parameter settings that are valid only for the individual device, and a few other set-
tings, are not saved. This includes:
– Instrument-specific parameters, such as OCXO Adjust
– Test mode settings, such as I/Q-Testsignal or Test Mode
– Limiter settings
– Port settings, such as in the Ethernet menu window
These settings remain valid regardless of which parameter set is currently loaded.
4.2 Saving Transmitter Information: Menu Item TxTool
In order to improve clarity and for archiving purposes, you can save transmitter data select-
ed via the web browser (such as logbook or device information, measurement values or pa-
rameters) to an ASCII or HTML file. You can also delete and restore logbook entries of the
transmitter components.
1. Select TxTool in the browser window.
A security query appears first of all.
State
Loaded Set Displays the active (i.e. loaded) parameter set
Operation State Display showing the status of the action that is being carried out (Ready,
Loading, Saving, Copying)
Current Set Changed Yellow: The device settings have been changed and no longer match
the settings of the loaded parameter set.
Names
Parameter Set 1 Name to describe the parameter set (e.g. intended use)
Parameter Set 2 See above
Parameter Set 3 See above
Parameter Set 4 See above
Parameter Set 5 See above
Parameter Set 6 See above
Parameter Set 7 See above
Parameter Set 8 See above
Function Description