Chapter 5 Operating
2104.6536.72 - 5.62 - E-1
5 Introduction to Manual Precorrection
Factory set precorrection curves v. manual precorrection
The transmitter equipment includes factory preset precorrection curves covering every fre-
quency range and all dynamic ranges. The appropriate precorrection curve is automatically
loaded in each case, so as a rule manual precorrection is not needed.
In certain cases the precorrection can be further optimized by manual precorrection. Pre-
correction can then be carried out for different frequencies and output powers. Since man-
ual precorrection does not overwrite any factory set precorrection curves, the factory
defaults can be restored at any time (see section "Characteristic Curves" in "Loading an ex-
isting characteristic curve").
User interface for manual precorrection
The corrector is operated with the aid of a web browser. The transmitter makes a Java ap-
plet (precorrector GUI) available for this purpose. This applet is launched in the web brows-
er and contains all the elements for operating the corrector.
The following section is a brief introduction to the configuration and use of this software.
This is followed by a description of the individual menus for setting the corrector.
5.1 Launching the Precorrector GUI
The precorrector GUI is integrated in the transmitter web browser interface. Before the pre-
corrector GUI is launched, therefore, the conditions must be created for remote operation
from a locally connected PC or remote control via a distant network client.
Note For further information on installing and configuring remote operation from a local PC or re-
mote control via a distant network client, refer to the section "Remote Operation and Re-
mote Control" earlier in this chapter.
1. From your browser, call the web GUI and log on with Configuration rights.
2. Launch the precorrector GUI by going to the Navigator window in the web GUI, below
the Precorrection entry, and double-clicking on Start Precorrector-GUI.
While the program is starting up, the message Starting ADE GUI will be displayed. After
a brief time, the initial operating window for the precorrector should appear.
Note An additional empty browser window will appear. If this window is closed, the Precorrector
GUI will also be terminated.
Note If the browser supports tabs (e.g. Internet Explorer 7), a new window is not created. The
precorrector GUI opens in a new tab instead.