Chapter 5 Operating
2104.6536.72 - 5.49 - E-1
3.2 Event Memory: Logbook Menu
The logbook is used to record changes in state (events) of the transmitter.
Menu windows
The Logbook menu branches to the following menu windows:
Summary: Complete logbook with all recorded data
Status: Partial logbook with recorded status changes
Warning: Partial logbook with recorded occurrences of warnings
Fault: Partial logbook with recorded occurrences of error messages
3.2.1 Logbook > Summary/Status/Warning/Fault
The complete logbook and the partial logbooks are uniformly structured. The messages are
numbered sequentially and contain the following information:
Identification for occurrence or disappearance of an event
Message: Brief description of the event
F The fan(s) failed; there is a high risk of overheating
Active Input 1 TS 1 is currently the active input
2 TS 2 is currently the active input
no No active input selected; test generator is activated
Data rate Ok Correct data rate on the active input
W Wrong data rate on the active input
Mute W RF signal is disabled by the signal processing unit in the exciter
Test signal Ok Transmitter has been switched to test mode
- OFF - Transmitter is in normal mode
Display LED Explanation