Chapter 5 Operating
2104.6536.72 - 5.25 - E-1
You can set multiple targets for error messages (alarm sinks).
Multiple communities can be set with Read Only authorization and Read/Write authori-
zation.
1.5.1.1 Settings on Transmitter Side
You can make settings yourself via the local display (if available), the web server or SNMP.
The menu windows of the SNMP menu contain all the settings that are required for access-
ing a transmitter.
Note Changes to these settings are adopted immediately. The device does not need to be re-
started.
Note Detailed information about the individual parameters can be found in the descriptions of the
respective menu windows.
1.5.1.2 Settings on Manager Side
To be able to monitor and control a transmitter with SNMP, the MIB of the device and a pro-
gram which can interpret the MIB must be available on the manager side.
You can load all available MIBs from any device using a web browser.
1. Log on using the web browser and select the SNMP Administration menu.
MIBs from Rohde&Schwarz and IRT are available. MIBs from IRT allow transmitters to
be linked using SNMP irrespective of the manufacturer. They are, however, limited with
respect to their functionality. When using IRT MIBs, you can select the "Inhibit Status"
for local operation (in the same way as for the parallel contacts). If this function is acti-